{"product_id":"pneumatic-peristaltic-pump-ipumpqd6s-b-7072ml-min","title":"Pneumatic Peristaltic Pump IPumpQD6S-B, 7072ml\/min","description":"\u003ch2 data-start=\"661\" data-end=\"680\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp data-start=\"681\" data-end=\"945\"\u003eThe IPumpQD6S-B Pneumatic Peristaltic Pump is designed for industrial fluid transfer in hazardous environments requiring safe, spark-free operation. Powered by pneumatic drive, this pump is suitable for explosion-risk areas where electric motors are not permitted.\u003c\/p\u003e\n\u003cp data-start=\"947\" data-end=\"1278\"\u003eWith a maximum flow rate of 7072 ml\/min and a stainless steel housing, it provides reliable performance, durability, and corrosion resistance for demanding industrial applications. Its peristaltic operating principle ensures fluid remains contained within the tubing, preventing contamination and reducing maintenance requirements.\u003c\/p\u003e\n\u003ch2 data-start=\"1280\" data-end=\"1307\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1309\" data-end=\"1705\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1309\" data-end=\"1334\"\u003e\n\u003ctr data-start=\"1309\" data-end=\"1334\"\u003e\n\u003cth data-start=\"1309\" data-end=\"1325\" data-col-size=\"sm\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"1325\" data-end=\"1334\" data-col-size=\"sm\" class=\"\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1359\" data-end=\"1705\"\u003e\n\u003ctr data-start=\"1359\" data-end=\"1401\"\u003e\n\u003ctd data-start=\"1359\" data-end=\"1371\" data-col-size=\"sm\"\u003ePump Type\u003c\/td\u003e\n\u003ctd data-start=\"1371\" data-end=\"1401\" data-col-size=\"sm\"\u003ePneumatic Peristaltic Pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1402\" data-end=\"1425\"\u003e\n\u003ctd data-start=\"1402\" data-end=\"1410\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-start=\"1410\" data-end=\"1425\" data-col-size=\"sm\"\u003eIPumpQD6S-B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1426\" data-end=\"1461\"\u003e\n\u003ctd data-start=\"1426\" data-end=\"1446\" data-col-size=\"sm\"\u003eMaximum Flow Rate\u003c\/td\u003e\n\u003ctd data-start=\"1446\" data-end=\"1461\" data-col-size=\"sm\"\u003e7072 ml\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1462\" data-end=\"1488\"\u003e\n\u003ctd data-start=\"1462\" data-end=\"1475\" data-col-size=\"sm\"\u003eDrive Type\u003c\/td\u003e\n\u003ctd data-start=\"1475\" data-end=\"1488\" data-col-size=\"sm\"\u003ePneumatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1489\" data-end=\"1524\"\u003e\n\u003ctd data-start=\"1489\" data-end=\"1505\" data-col-size=\"sm\"\u003eSafety Rating\u003c\/td\u003e\n\u003ctd data-start=\"1505\" data-end=\"1524\" data-col-size=\"sm\"\u003eExplosion-Proof\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1525\" data-end=\"1563\"\u003e\n\u003ctd data-start=\"1525\" data-end=\"1544\" data-col-size=\"sm\"\u003eHousing Material\u003c\/td\u003e\n\u003ctd data-start=\"1544\" data-end=\"1563\" data-col-size=\"sm\"\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1564\" data-end=\"1601\"\u003e\n\u003ctd data-start=\"1564\" data-end=\"1586\" data-col-size=\"sm\"\u003eOperation Principle\u003c\/td\u003e\n\u003ctd data-start=\"1586\" data-end=\"1601\" data-col-size=\"sm\"\u003ePeristaltic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1602\" data-end=\"1645\"\u003e\n\u003ctd data-start=\"1602\" data-end=\"1616\" data-col-size=\"sm\"\u003eApplication\u003c\/td\u003e\n\u003ctd data-start=\"1616\" data-end=\"1645\" data-col-size=\"sm\"\u003eIndustrial Fluid Transfer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1646\" data-end=\"1685\"\u003e\n\u003ctd data-start=\"1646\" data-end=\"1663\" data-col-size=\"sm\"\u003eSuitable Media\u003c\/td\u003e\n\u003ctd data-start=\"1663\" data-end=\"1685\" data-col-size=\"sm\"\u003eCompatible Liquids\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1686\" data-end=\"1705\"\u003e\n\u003ctd data-start=\"1686\" data-end=\"1698\" data-col-size=\"sm\"\u003eCondition\u003c\/td\u003e\n\u003ctd data-start=\"1698\" data-end=\"1705\" data-col-size=\"sm\"\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 data-start=\"1707\" data-end=\"1722\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"1723\" data-end=\"1927\"\u003e\n\u003cli data-start=\"1723\" data-end=\"1748\"\u003e\n\u003cp data-start=\"1725\" data-end=\"1748\"\u003ePneumatic motor drive\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1749\" data-end=\"1783\"\u003e\n\u003cp data-start=\"1751\" data-end=\"1783\"\u003eExplosion-proof safe operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1784\" data-end=\"1819\"\u003e\n\u003cp data-start=\"1786\" data-end=\"1819\"\u003eFlow capacity up to 7072 ml\/min\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1820\" data-end=\"1860\"\u003e\n\u003cp data-start=\"1822\" data-end=\"1860\"\u003eStainless steel housing construction\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1861\" data-end=\"1887\"\u003e\n\u003cp data-start=\"1863\" data-end=\"1887\"\u003eNon-contact fluid path\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1888\" data-end=\"1927\"\u003e\n\u003cp data-start=\"1890\" data-end=\"1927\"\u003eDesigned for hazardous environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"1929\" data-end=\"1952\"\u003eTypical Applications\u003c\/h2\u003e\n\u003cul data-start=\"1953\" data-end=\"2105\"\u003e\n\u003cli data-start=\"1953\" data-end=\"1983\"\u003e\n\u003cp data-start=\"1955\" data-end=\"1983\"\u003eChemical processing plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1984\" data-end=\"2014\"\u003e\n\u003cp data-start=\"1986\" data-end=\"2014\"\u003eHazardous industrial zones\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2015\" data-end=\"2043\"\u003e\n\u003cp data-start=\"2017\" data-end=\"2043\"\u003eSolvent transfer systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2044\" data-end=\"2073\"\u003e\n\u003cp data-start=\"2046\" data-end=\"2073\"\u003eIndustrial dosing systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2074\" data-end=\"2105\"\u003e\n\u003cp data-start=\"2076\" data-end=\"2105\"\u003eExplosion-risk environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"2107\" data-end=\"2128\"\u003eShipping \u0026amp; Support\u003c\/h2\u003e\n\u003cul data-start=\"2129\" data-end=\"2240\"\u003e\n\u003cli data-start=\"2129\" data-end=\"2146\"\u003e\n\u003cp data-start=\"2131\" data-end=\"2146\"\u003eFast dispatch\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2147\" data-end=\"2182\"\u003e\n\u003cp data-start=\"2149\" data-end=\"2182\"\u003eAustralia \u0026amp; world-wide shipping\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2183\" data-end=\"2217\"\u003e\n\u003cp data-start=\"2185\" data-end=\"2217\"\u003eTechnical assistance available\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2218\" data-end=\"2240\"\u003e\n\u003cp data-start=\"2220\" data-end=\"2240\"\u003eWarranty available\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"AMG Hydraulic Engineering","offers":[{"title":"Default Title","offer_id":49989943492801,"sku":"1601667061776","price":2802.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0852\/7767\/1617\/files\/Hb0f6fb6fe42d4fd29454b3212b90d798J.webp?v=1771397425","url":"https:\/\/amghydraulics.com\/products\/pneumatic-peristaltic-pump-ipumpqd6s-b-7072ml-min","provider":"AMG Hydraulic Engineering","version":"1.0","type":"link"}